This is a working overview of mobile phase, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-03-15 and is reviewed periodically as new material appears.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
| Property | Value | Notes |
|---|---|---|
| Abbreviation | HPLC | Also called high-performance liquid chromatography |
| Separation mechanism | Differential partitioning | Compounds distribute between mobile and stationary phases |
| Typical column chemistry | C18 (octadecylsilane) | Used in reversed-phase separations |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is common for trace and confirmatory work |
| Typical particle size | 1.8–5 µm | Smaller particles require higher pressure and can improve speed |
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
The exact size of the GPCR superfamily is unknown, but at least 831 different human genes (or about 4% of the entire protein-coding genome) have been predicted to code for them from genome sequence analysis. Although numerous classification schemes have been proposed, the superfamily was classically divided into three main classes (A, B, and C) with no detectable shared sequence homology between classes. The largest class by far is class A, which accounts for nearly 85% of the GPCR genes. Of class A GPCRs, over half of these are predicted to encode olfactory receptors, while the remaining receptors are liganded by known endogenous compounds or are classified as orphan receptors. Despite the lack of sequence homology between classes, all GPCRs have a common structure and mechanism of signal transduction. The very large rhodopsin A group has been further subdivided into 19 subgroups (A1-A19). According to the classical A-F system, GPCRs can be grouped into six classes based on sequence homology and functional similarity:
The role of the other BDNF receptor, p75, is less clear. While the TrkB receptor interacts with BDNF in a ligand-specific manner, all neurotrophins can interact with the p75 receptor. When the p75 receptor is activated, it leads to activation of NFkB receptor. Thus, neurotrophic signaling may trigger apoptosis rather than survival pathways in cells expressing the p75 receptor in the absence of Trk receptors. Recent studies have revealed a truncated isoform of the TrkB receptor (t-TrkB) may act as a dominant negative to the p75 neurotrophin receptor, inhibiting the activity of p75, and preventing BDNF-mediated cell death.
The following classification system for transmembrane solute transporters has been constructed in the TCDB. Three families of ABC exporters are defined by their evolutionary origins. ABC1 exporters evolved by intragenic triplication of a 2 TMS precursor (TMS = transmembrane segment. A "2 TMS" protein has 2 transmembrane segments) to give 6 TMS proteins. ABC2 exporters evolved by intragenic duplication of a 3 TMS precursor, and ABC3 exporters evolved from a 4 TMS precursor which duplicated either extragenicly to give two 4 TMS proteins, both required for transport function, or intragenicly to give 8 or 10 TMS proteins. The 10 TMS proteins appear to have two extra TMSs between the two 4 TMS repeat units. Most uptake systems (all except 3.A.1.21) are of the ABC2 type, divided into type I and type II by the way they handle nucleotides. A special subfamily of ABC2 importers called ECF use a separate subunit for substrate recognition. ABC1 (InterPro: IPR036640): ABC2 (InterPro: IPR000412 [partial]): ABC3 (InterPro: IPR003838):
The Analytical Information Markup Language (AnIML) is an open ASTM XML standard for storing and sharing analytical chemistry and biological data. A main reason of using AnIML is that FAIR data (Findable, Accessible, Interoperable and Reusable) standards are automatically implemented. As AnIML's structure is human-readable, Accessibility is given. Interoperability, Reusability and Findability are secured by the AnIML Core and AnIML Technique Definitions. AnIML has been continuously worked on starting from 2003 up to 2020. The last AnIML Core Version update happened in 2010. So far, no standardisation document nor public example files have been published. The standard exists only in pre-release form. AnIML is a XML standard which consists of two logical layers:
Coiled-coil α helices are highly stable forms in which two or more helices wrap around each other in a "supercoil" structure. Coiled coils contain a highly characteristic sequence motif known as a heptad repeat, in which the motif repeats itself every seven residues along the sequence (amino acid residues, not DNA base-pairs). The first and especially the fourth residues (known as the a and d positions) are almost always hydrophobic; the fourth residue is typically leucine – this gives rise to the name of the structural motif called a leucine zipper, which is a type of coiled-coil. These hydrophobic residues pack together in the interior of the helix bundle. In general, the fifth and seventh residues (the e and g positions) have opposing charges and form a salt bridge stabilized by electrostatic interactions. Fibrous proteins such as keratin or the "stalks" of myosin or kinesin often adopt coiled-coil structures, as do several dimerizing proteins. A pair of coiled-coils – a four-helix bundle – is a very common structural motif in proteins. For example, it occurs in human growth hormone and several varieties of cytochrome. The Rop protein, which promotes plasmid replication in bacteria, is an interesting case in which a single polypeptide forms a coiled-coil and two monomers assemble to form a four-helix bundle.
Sources: en.wikipedia.org
Arthur 'Blaine' Bowman (born 1946 in Ogden, Utah, USA) is a leading proponent of ion chromatography, who has served variously as chairman, president, chief executive officer, and director of Dionex Corporation, a manufacturer of analytical instruments. Bowman received the 2015 Pittcon Heritage Award in recognition of his contributions to the field of ion chromatography. Arthur 'Blaine' Bowman was born in 1946 in Ogden, Utah, US. Around age 10, his family moved to Southern California, where he grew up. Bowman attended Brigham Young University in Provo, Utah in the physics program. As an undergraduate, he worked in the summer as an engineer at McDonnell Douglas, testing modules for the Apollo rocket. Bowman received his B.S. in physics in 1970. Next, Bowman worked as a product engineer at Motorola's Semiconductor Products Division in Phoenix, Arizona, where he became interested in business. He attended Stanford University's school of business from 1971 to 1973, receiving his M.B.A. in 1973. He then joined McKinsey & Company as a management consultant.
Several case studies studying deletions in the 7p22.3 genomic region, where the SNX8 gene is located, found that it contributes to neurodevelopmental problems with considerable impairments in the motor, cognitive and socio-emotional areas, with malformations in the heart and craniofacial structures, with developmental, intellectual and language delay, with mild intellectual disability and with cognitive impairment associated with autism in some cases. This idea is supported by the fact that the overlapping deleted regions of the different patients of these studies contained SNX8, which suggests that it is one of the accountable genes.
Gas phase ion chemistry is a field of science encompassed within both chemistry and physics. It is the science that studies ions and molecules in the gas phase, most often enabled by some form of mass spectrometry. By far the most important applications for this science is in studying the thermodynamics and kinetics of reactions. For example, one application is in studying the thermodynamics of the solvation of ions. Ions with small solvation spheres of 1, 2, 3... solvent molecules can be studied in the gas phase and then extrapolated to bulk solution. Transition state theory is the theory of the rates of elementary reactions which assumes a special type of chemical equilibrium (quasi-equilibrium) between reactants and activated complexes. RRKM theory is used to compute simple estimates of the unimolecular ion decomposition reaction rates from a few characteristics of the potential energy surface.
Brenipatide (INNTooltip International Nonproprietary Name, USANTooltip United States Adopted Name; developmental code name LY-3537031) is a dual agonist of glucagon-like peptide-1 (GLP-1) receptors and gastric inhibitory polypeptide (GIP) receptors. Brenipatide is under development by Eli Lilly and Company for the treatment of alcoholism, bipolar disorder, asthma, smoking withdrawal, cardiovascular disorders, liver disorders, metabolic disorders, and obesity. It is taken by subcutaneous injection once per month. The drug has a longer elimination half-life than tirzepatide or retatrutide. As of December 2025, it was in phase 3 clinical trials for alcoholism and bipolar disorder, phase 2 trials for asthma and smoking withdrawal, and phase 1 trials for cardiovascular disorders, liver disorders, metabolic disorders, and obesity. List of investigational antipsychotics List of investigational bipolar disorder drugs List of investigational substance-related disorder drugs
Sources: en.wikipedia.org
June 13 – 23: 2019 Men's Softball World Championship in Prague-Havlíčkův Brod Argentina defeated Japan, 3–2, to win their first Men's Softball World Championship title. Canada took third place. July 23 – 27: Europe/Africa Softball 2020 Olympic Qualifier in Utrecht Italy defeated Great Britain, 5–0, to book their team and compete at the 2020 Summer Olympics. July 26 – 30: 2019 Women's U12 Softball World Cup in Tainan (debut event) Chinese Taipei defeated Peru, 3–2, to win the inaugural Women's U12 Softball World Cup title. The Czech Republic took third place. Indonesia took fourth place. August 10 – 17: 2019 Women's U19 Softball World Cup in Irvine The United States defeated Japan, 4–3, to win their third consecutive and seventh overall Women's U19 Softball World Cup title. Canada took third place. August 25 – September 1: Americas Softball 2020 Olympic Qualifier in Surrey Champions: Mexico; Second: Canada; Third: Puerto Rico Note: Both Mexico and Canada have qualified to compete at the 2020 Summer Olympics. September 24 –28: Asia/Oceania Softball 2020 Olympic Qualifier in Shanghai Champions: Australia; Second: Chinese Taipei; Third: China Note: Australia has qualified to compete at the 2020 Summer Olympics.
Eculizumab (Soliris) appears to be useful for atypical hemolytic uremic syndrome (aHUS). In September 2011 the U.S. Food and Drug Administration (FDA) approved it as an orphan drug to treat people with aHUS. This approval was based on two small prospective trials of 17 people and 20 people. In the UK, NICE issued guidance on the use of Eculizumab for treating aHUS, based on five evidence sources, including those used by the FDA No randomised controlled trials were identified. All prospective studies were phase 2, open‑label, non‑randomised, single‑arm studies that included patients with different clinical baseline characteristics. The prospective studies lasted 26 weeks; however, patients were allowed to continue treatment with eculizumab in a long‑term extension study. Ravulizumab-cwvz (Ultomiris) is a second generation monoclonal antibody for aHUS made by Alexion pharmaceuticals, Inc. The target of ravulizumab-cwvz is the same eculizumab (Soliris) with changes to the structure of the antibody resulting in a longer serum half life and therefore reduced dosing regimen.
1,3-Beta-glucan synthase is a glucosyltransferase enzyme involved in the generation of beta-glucan in fungi. It serves as a pharmacological target for antifungal drugs such as caspofungin, anidulafungin, and micafungin, deemed 1,3-Beta-glucan synthase inhibitors. Under the CAZy classification system, fungi and plant members fall in the glycosyltransferase 48 family (GT48). Some members of the glycosyltransferase 2 family (Pfam PF13632), such as the curdlan synthase CrdS (Q9X2V0), also has a similar activity. The biosynthesis of disaccharides, oligosaccharides, and polysaccharides involves the action of hundreds of different glycosyltransferases. These enzymes catalyse the transfer of sugar moieties from activated donor molecules to specific acceptor molecules, forming glycosidic bonds. The family consists of various 1,3-beta-glucan synthase components including Gls1, Gls2, and Gls3 from yeast. 1,3-Beta-glucan synthase (EC 2.4.1.34.) also known as callose synthase catalyses the formation of a beta-1,3-glucan polymer that is a major component of the fungal cell wall. The reaction catalysed is:
To determine saponification value, the sample is treated with an excess of alkali (usually an ethanolic solution of potassium hydroxide) for half an hour under reflux. The KOH is consumed by reaction with triglycerides, which consume three equivalents of base. Diglycerides consume two equivalents of KOH. Monoglycerides and free fatty acids, as well as other esters such as lactones, consume one equivalent of base. At the end of the reaction the quantity of KOH is determined by titration using standard solution of hydrochloric acid (HCl). Key to the method is the use of phenolphthalein indicator, which indicates the consumption of strong base (KOH) by the acid, not the weak base (potassium carboxylates). The SV (mg KOH/ g of sample) is calculated as following: Eq. 1 where: B {\displaystyle {\textrm {B}}} is the volume of HCl solution used for the blank run, in mL; S {\displaystyle {\textrm {S}}} is the volume of HCl solution used for the tested sample, in mL; M {\displaystyle {\textrm {M}}} is the molarity of HCl solution, in mol / L; 56.1 is the molecular weight of KOH, in g / mol; W
The inverted terminal repeat (ITR) sequences comprise 145 bases each. They were named so because of their symmetry, which was shown to be required for efficient multiplication of the AAV genome. The feature of these sequences that gives them this property is their ability to form a hairpin, which contributes to so-called self-priming that allows primase-independent synthesis of the second DNA strand. The ITRs were also shown to be required for both integration of the AAV DNA into the host cell genome (19th chromosome in humans) and rescue from it, as well as for efficient encapsidation of the AAV DNA combined with generation of a fully assembled, deoxyribonuclease-resistant AAV particles. With regard to gene therapy, ITRs seem to be the only sequences required in cis next to the therapeutic gene: structural (cap) and packaging (rep) proteins can be delivered in trans. With this assumption many methods were established for efficient production of recombinant AAV (rAAV) vectors containing a reporter or therapeutic gene. However, it was also published that the ITRs are not the only elements required in cis for the effective replication and encapsidation. A few research groups have identified a sequence designated cis-acting Rep-dependent element (CARE) inside the coding sequence of the rep gene. CARE was shown to augment the replication and encapsidation when present in cis.
Sources: en.wikipedia.org
It measures the presence and amount of one or more compounds in a liquid sample. Separation occurs in a column, and detection produces a signal proportional to concentration. Identification usually requires comparison with a known reference standard under the same conditions.
In most cases the sample is consumed or altered during analysis, though some detectors are non-destructive. Fractions can be collected after separation for further study. Repeated testing therefore requires additional sample.
Run times range from under a minute for fast methods to over an hour for complex separations. Sample preparation, equilibration, and data review add time. Throughput depends on instrument configuration and method requirements.
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.