accuracy raises a handful of sensible questions. This page answers them in order, starting with the fundamentals and moving to applications.
This page was last updated on 2025-10-05 and is reviewed periodically as new material appears.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
In May 2023, the FDA approved the iLet Bionic Pancreas system for people with Type 1 diabetes of six years and older. The device uses a closed-loop system to deliver both insulin and glucagon in response to sensed blood glucose levels. The 4th generation iLet prototype, presented in 2017, is around the size of an iPhone, with a touchscreen interface. It contains two chambers for both insulin and glucagon, and the device is configurable for use with only one hormone, or both. A 440-patient study of type I diabetes ran in 2020 and 2021 using a device configuration that delivered only insulin in comparison to standard of care; device use led to better circulating glucose control (measured by continuous monitoring) and a reduction in glycated hemoglobin (versus no change for the standard of care group). However, the incidence of severe hypoglycemic events was more than 1.5 times higher among device users versus standard care patients. There are several non-commercial, non-FDA approved DIY options, using open source code, including OpenAPS, Loop, and/or AndroidAPS.
Viral induction of apoptosis occurs when one or several cells of a living organism are infected with a virus, leading to cell death. Cell death in organisms is necessary for the normal development of cells and the cell cycle maturation. It is also important in maintaining the regular functions and activities of cells. Viruses can trigger apoptosis of infected cells via a range of mechanisms including:
Cyanobacteria are the simplest organisms that have been observed demonstrating circadian rhythms.(2)(3) The primitiveness and simplicity make the KaiC phosphorylation model invaluable to circadian rhythm research. While it is much simpler than models for eukaryotic circadian rhythm generators, the principles are largely the same. In both systems the circadian period is dependent on the interactions between proteins within the cell, and when the genes for those proteins are mutated, the expressed period changes. (1)(2) This model of circadian rhythm generation also has implications for the study of circadian “evolutionary biology”. Given the simplicity of cyanobacteria and of this circadian system, it may be safe to assume that eukaryotic circadian oscillators are derived from a system similar to that present in cyanobacterium. (1) Bacterial circadian rhythm
Group specificity occurs when an enzyme will only react with molecules that have specific functional groups, such as aromatic structures, phosphate groups, and methyls. One example is pepsin, an enzyme that is crucial in digestion of foods ingested in our diet, that hydrolyzes peptide bonds in between hydrophobic amino acids, with recognition for aromatic side chains such as phenylalanine, tryptophan, and tyrosine. Another example is hexokinase, an enzyme involved in glycolysis that phosphorylates glucose to produce glucose-6-phosphate. This enzyme exhibits group specificity by allowing multiple hexoses (6 carbon sugars) as its substrate. Glucose is one of the most important substrates in metabolic pathways involving hexokinase due to its role in glycolysis, but is not the only substrate that hexokinase can catalyze a reaction with.
The ASA is closely related to the concept of the solvent-excluded surface (also known as the Connolly's molecular surface area or simply Connolly surface), which is imagined as a cavity in bulk solvent. It is also calculated in practice via a rolling-ball algorithm developed by Frederic Richards and implemented three-dimensionally by Michael Connolly in 1983 and Tim Richmond in 1984. Connolly spent several more years perfecting the method. Implicit solvation Van der Waals surface VADAR tool for analyzing peptide and protein structures Relative accessible surface area
Sources: en.wikipedia.org
Volanesorsen was approved by the European Medicines Agency (EMA) for the treatment of familial chylomicronaemia syndrome in May 2019. In January 2013 mipomersen (marketed as Kynamro) was approved by the FDA for the treatment of homozygous familial hypercholesterolemia. Inotersen received FDA approval for the treatment of hereditary transthyretin-mediated amyloidosis in October 2018. The application for inotersen was granted orphan drug designation. It was developed by Ionis Pharmaceuticals and licensed to Akcea Therapeutics. Patisiran (sold under Onpattro) was developed by Alnylam Pharmaceuticals, and also approved for use in the US and EU in 2018 with orphan drug designation. Its mechanism-of-action is the active substance of small interfering RNA (siRNA), which allows it to interfere with and block the production of transthyretin. As such, it was the first FDA-approved siRNA therapeutic.
Pandey has the Human Proteome Organization(HUPO)'s Discovery in Proteomic Sciences Award. The Wellcome Trust/DBT India Alliance named him a Margdarshi Fellow, and he established a Center for Molecular Medicine at NIMHANS in Bangalore as a result. He is an Associate Editor of Clinical Proteomics and a member of the Editorial Boards of Molecular and Cellular Proteomics, Proteomics, and the Journal of Clinical Investigation. He has received the Howard Temin Award from the National Cancer Institute, the Experimental Pathologist-In-Training Award from the American Society for Investigative Pathology, and the Sidney Kimmel Scholar Award from the Sidney Kimmel Foundation for Cancer Research. The United States Department of Defense also bestowed upon him the Era of Hope Scholar Award.
ACS first established technical divisions in 1908 to foster the exchange of information among scientists who work in particular fields of chemistry or professional interests. Divisional activities include organizing technical sessions at ACS meetings, publishing books and resources, administering awards and lectureships, and conducting other events. The original five divisions were 1) organic chemistry, 2) industrial chemists and chemical engineers, 3) agricultural and food chemistry, 4) fertilizer chemistry, and 5) physical and inorganic chemistry. As of 2016, there are 32 technical divisions of ACS.
The American Society for Quality (ASQ), formerly the American Society for Quality Control (ASQC), is a society of quality professionals, with more than 30,000 members, in more than 140 countries. ASQC was established on 16 February 1946 by 253 members in Milwaukee, Wisconsin, with George D. Edwards as its first president. The organization was first created as a way for quality experts and manufacturers to sustain quality-improvement techniques used during World War II. In 1948, ASQC's Code of Ethics established standards for members to conduct their activities and business. Business writer Armand V. Feigenbaum served as president of the society in 1961–63. In 1997, the members of the organization voted to change its name from "American Society for Quality Control" to "American Society for Quality".
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
It is a set of checks performed before or during an HPLC run to confirm the system works as expected. Parameters may include resolution, tailing factor, theoretical plates, and retention time precision. Failure can trigger maintenance, method adjustment, or repeat analysis.